What is not allowed when using dental high-speed handpiece in dental clinic?

2022-09-26  This post is in

As a professional dental handpiece factory, we Rundental pay attention to the using of dental handpieces.

As a professional dental handpiece manufacturer, we Rundental dental handpiece factory not only sell high quality dental high speed handpiece and low speed dental handpiece to dental importer or dental dealers, but also often give dentists some notes on the use of dental handpiece to help them understand more about dental driller in order to improve dental hygiene and extend the life of dental handpieces in dental clinics.

So, what is not allowed when using dental high-speed handpiece in dental clinic?

It is forbidden to use a dental handpiece bur with a shank that is not up to standard.We have written a previous article about the categories of dental burs for your reference.

Tips of using dental handpiece

In the process of using the dental air turbine, if you find the following problems occur, you should stop using that air-driven dental handpiece immediately and call the dental technician to do professional dental equipment after-sales service.

  1. Abnormal sound
  2. Dental bur oscillating badly
  3. Poor cooling of dental air rotor
  4. Dental bur has moved
  5. Powerless cutting force
dental handpiece used with bur
dental handpiece used with bur

It is forbidden to use a dental diamond bur or dental carbide bur which has been bent or deformed.You can refer to our previous article about What is a diamond bur used for in dentistry.

Tips of extending lifespan of dental handpiece

  1. Dental handpeice clamping system is not durable, or the air rotor can not clamp the bur tightly, so you will need to check whether the use of the shank does not meet the standard of the dental bur, or the use of poor quality dental handpiece bur has been damaged the movement.
  2. Do not adjust higher air pressure from dental chair by yourself because of the bur didn’t work, most of the time because the bur of dental handpeice is blunt, it is recommended to replace the dental handpiece bur.
dental turbine with diamond bur
  • It is not allowed to press the back cover before the dental handpiece is completely stopped.
the dental turbine is working
  • Dry heat disinfection and chemical liquid immersion disinfection are not allowed, but the high temperature and high pressure steam dental disinfection is recommended.
high pressure steam dental disinfection for dental instruments
  • Do not use the dental handpiece until it has been sterilized.
Dental handpeice are waiting for sterilized
  • Do not send unsterilized dental handpieces for dental handpiece repair.
sterilizing the used dental handpiece

More tips

These are the issues that need special attention when using dental high-speed handpieces in the clinic. If you want more information about professional usage and maintenance of dental slow speed handpiece and dental increasing speed handpiece, welcome to send us emails and messages.