What to Do When Using China Dental Drills?

This article introduces some considerations for the clinical use of dental bur.
Unregulated habits and methods of using the China dental bur may damage the dental diamond bur itself and China dental handpiece or bring safety crisis to the dentists and patients. So,what to do when using China dental drills?
1.Choose the right dental burs for dental handpiece
Should choose such a China dental drill: not easy to deformation, with high stability and resistance to fracture, no tip chipping or desanding, good concentricity in rotation.

2.Use suitable rotational speed
Should pay attention to the rotational speed of the dental burr, especially when operating a large diameter bur and coarse grain bur, the dental handpiece bur rotational speed is too high will generate too much heat, resulting in damage to the pulp and dental tissue.
3.Do not force a turning dental bur for dental handpiece
Do not force the turning dental diamond bur into the dental turbine handpiece, if installation difficulties occur check the China dental handpiece and the turning bur carefully.

4.Use suitable force
Cutting should be applied to the appropriate force (30 ~ 60g), sequential and effective cutting dental tissue.
5.Be disinfected and sterilized before each use of the China dental bur
The turning dental burs should be disinfected and sterilized before each use. Nylon brush or ultrasonic cleaner should be used frequently to clean the China dental drills. Autoclave the needle at 135 degrees for at least 10 minutes.
6.Check the FG logo of the dental bur carefully
Pay attention to the FG logo on the package, which identifies the turning dental drills used on dental high-speed turbines.

7.Store it in a clean environment
After sterilization or cleaning, dry the dental diamond bur and store it in a clean and moisture-free environment.
8. Do not use chlorine-containing disinfectant
After using dental tungsten bur, should be cleaned after using high temperature and high pressure disinfection, do not use chlorine-containing disinfectant soaked bur, otherwise it will cause tungsten bur rust blunt.
9.Cooling water should reach 50ml per minute
The use of dental turbine handpiece cooling water should reach 50ml per minute.
10.Replace the new dental diamond bur in time
The tip of the common clinical dental diamond bur wears out faster than the tail end, at this time you should replace the new dental diamond bur in time to avoid low efficiency of the dental bur cutting.
We Rundental offer high quality dental burs, if you need to import dental burs from China, please send inquiry to us.